Pasia Industries Ltd

PASIA INDUSTRIES LTD ————​Leading MI Cable Heating

Manufacturer from China
Active Member
5 Years
Home / Products / Electric Heat Tracing /

Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal

Contact Now
Pasia Industries Ltd
Province/State:zhejiang
Country/Region:china
Contact Person:Warren Sun
Contact Now

Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal

Ask Latest Price
Video Channel
Brand Name :MICH
Model Number :EHTTSOTU
Certification :ISO9001
Place of Origin :China
MOQ :1 meter
Price :USD0.5-USD5 per meter
Supply Ability :10 million meters per year
Delivery Time :in one month
Packaging Details :plywood crates
Dimensions :0.2"x0.3" (5mm x 8mm) 12 AWG
Dielectric Strength :Over 2000 volts
Property :Explosion-proof, anti-corrosion, safe
Usage :Oil Terminal
Distance :up to long distance
Wattage :39Watt/meter
Max. Exposure Temp. (°F) Power Off :260
Voltages :Up to 480
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Electric Heat Tracing Technical Solution for Oil Terminal Use is an electric heat trace technology package which can be selected to be used on the pipelines, tanks, valves etc related to the oil terminals based on the project conditions and requirement. In winter, the climate is cold and the temperature is too low, which may lead to serious blockage of the oil pipeline when it arrives at the gathering and transmission pump station due to the heat loss and wind speed, etc., and the material in the pipeline cannot be normally transported. In order to solve the problem of oil pipeline freezing, the electric heat tracing solution should be used to heat all the main pipelines on the wharf.


Through the field investigation, including the local temperature, low temperature, wind speed, and from the safety point of view, for the long oil transmission pipeline of large diameter, the occasion of high heat tracking temperature, and combined with the heat loss of comprehensive consideration, the constant power electric heating trace should be used, because the highest maintenance temperature can reach 150℃, and the highest exposure temperature is 205 degrees, which can completely maintain the normal operation of the oil pipeline. For longer pipelines, the use of series constant power electric heating insulation products, the electric tracing is large and the service length is longer, up to thousands of meters. While for the transmission distance is not long, for higher safety, corrosion resistance consideration and other high requirements, mineral insulation heating cable can be considered. For the distance to be at least 5 kilometers, the skin effect heating solution can be considered.


The series constant power electric heating tracing product is 5~12 times longer than the general constant power and self-limiting temperature electric tracing, so it is especially suitable for long distance transmission pipelines in petroleum, chemical industry, electric power, wharf and other industries.


In the performance of electric heat trace products, the outer layer of electric tracing belt has metal shielding braided layer, which not only has the function of heat transfer and heat dissipation, but also can improve the overall tensile strength of electric heating, and can also be used as a safe grounding wire.

Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal

Table 2 Heating Cable Specification (600V Single Conductor)

Cable Code Diameter HDPE Diameter Standard resistance value at +20 Maximum Production Length Unit weight
mm mm Ω/m m kg/km
16C1.7 8.2 10 0.0017 350 366.54
16C2.2 7.6 9.4 0.0022 380 307.77
16C2.9 7.0 8.8 0.0029 400 264.45
16C4 5.9 7.7 0.004 600 190.88
16C7 5.3 7.1 0.007 600 154.08
16C11 4.9 6.7 0.011 600 132.25
16C13 4.6 6.4 0.013 600 (300)☆ 125.7
16C17 4.6 6.4 0.017 600 (300)☆ 117.16
16C21 4.6 6.4 0.021 600 (300)☆ 111.9
16C25 3.7 5.5 0.025 600 (480)☆ 68.83
16C33 3.7 5.5 0.033 600 (480)☆ 63.76
16C40 3.4 5.2 0.04 600 (560)☆ 58.87
16C63 3.2 5 0.063 600 51.47
16K80 6.8 8.6 0.08 370 (140)☆ 254.18
16K100 5.2 7 0.1 450 (240)☆ 162.11
16K140 4.9 6.7 0.14 600 (270)☆ 122.55
16K197 4.45 6.25 0.197 600 (330)☆ 111.32
16K220 4.5 6.3 0.22 600 (330)☆ 102.89
16K315 4.3 6.1 0.315 600 (350)☆ 91.44
16K345 4.2 6.0 0.345 600 (370)☆ 85.9
16K450 4.0 5.8 0.45 600 (400)☆ 80.73
16K630 4.0 5.8 0.63 600 (400)☆ 77.26
16K800 3.5 5.3 0.8 600 (530)☆ 61.48
16K1250 2.8 4.6 1.25 600 40.83
16K2000 2.8 4.6 2.0 600 38.96

Table 3 Heating Cable Specification (600V Double Conductors)

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
26C3.4 12.9 0.0034 150 783.76
26C4.4 12.2 0.0044 160 701.56
26C5.8 11.3 0.0058 170 606.16
26C8.6 9.90 0.0086 180 451.43
26C11.4 9.30 0.0114 200 400.05
26C13.8 9.00 0.0138 210 375.20
26C17.2 8.60 0.0172 220 344.90
26C23 8.00 0.023 250 303.25
26C34.4 7.50 0.0344 280 269.20
26C49.2 7.10 0.0492 300 243.84
26K240 9.90 0.24 180 451.43
26K320 9.30 0.32 200 400.05
26K384 9.00 0.384 210 375.20
26K480 8.60 0.48 220 344.90
26K640 8.00 0.64 250 303.25
26K960 7.50 0.96 280 269.20

Table 4 Heating Cable Specification (300V Double Cores)

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
23C3.4 12.0 0.0034 200 708.10
23C4.4 11.3 0.0044 220 629.07
23C5.8 10.4 0.0058 240 537.73
23C8.6 9.00 0.0086 260 392.56
23C11.4 8.40 0.0114 280 343.89
23C13.8 8.00 0.0138 300 314.57
23C17.2 7.60 0.0172 320 286.27
23C23 7.10 0.023 340 252.98
23C34.4 6.60 0.0344 360 221.19
23C49.2 6.20 0.0492 380 197.64
23K160 10.4 0.16 220 508.37
23K240 9.00 0.24 240 392.56
23K320 8.40 0.32 265 343.89
23K384 8.00 0.384 280 314.57
23K480 7.70 0.48 300 291.91
23K640 7.10 0.64 320 252.98
23K960 6.50 0.96 350 216.11

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals;

Mark of (300)☆ is a recommended production length by MICH

Selection Parameters:

Constant Wattage Heating Cable High Temperature Heating cable Polyamide/Fiberglass Heating Cable Harsh Environment Heating Cable General Purpose Heating Cable
Available Voltages 120, 208, 240, 277 & 480 VAC 120, 208, 240, 277 & 480 VAC 120, 208, 240, 277 & 480 VAC 120, 208, 240, 277 & 480 VAC

Available Wattages

4, 8 & 12 watts/ft (13, 26 & 39 watts/m) 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) 4, 8 & 12 watts/ft (13, 26 & 39 watts/m) 3, 5, 8 & 12 watts/ft (10, 16, 26 & 39 watts/m)
Maximum Exposure Temperature

500°F (260°C)

500°F (260°C)

500°F (260°C)

400°F (204°C)

Nominal Dimensions

0.2"x0.3" (5mm x 8mm) 12 AWG

0.2"x0.3" (5mm x 8mm) 12 AWG

0.2"x0.3" (5mm x 8mm) 12 AWG

0.2"x0.3" (5mm x 8mm) 12 AWG
Resistance to Moisture Good Good

Excellent

Excellent

Resistance to Chemicals Good Good

Excellent

Excellent

Resistance to Flame Excellent Outstanding Excellent Outstanding
Dielectric Strength Over 2000 volts

Over 2000 volts

Over 2000 volts Over 2000 volts
Inquiry Cart 0